UTILIZATION OF THE UNIVERSAL BOILER FOR COMBUSTION OF WHOLE BALES OF HAY
Recently, the attractiveness of energy crops for burning has increased namely in the field of agriculture. This mainly involves burning hay harvested from permanent grass stands, especially meadows and pastures.Universal boiler for burning (not only) whole bales of straw
Biomass-fired boilers with outputs ranging from 100 to 1,000 kW are now mostly designed for either burning straw or waste wood.Biomass boiler room
The construction of the biomass-fired boiler plant with a boiler for burning whole bales of straw and energy crops at Step TRUTNOV a.s. was completed and put ...Florcenter Olomouc
Stages I. and II. of building biomass boiler room in Flor center Olomouc have been completed. The boiler room is exceptional in that it burns whole packs of straw...Vacancies
In connection with production expansion, the company will establish workers to the following positions: welder with basic training in accordance with official standards EN 287-1 111 and EN 287-1 135. Also a project engineer to dealing with orders from abroad - language qualifications needed.Map
WATER HEATERS
Besides the standard types, the water heaters can be customised to casing/insert pressure up to 4.0 MPa, temperature up to 150 °C, and volume from 0.25 to 10.0 m3. Special types of water heaters for pressure above 1.6 MPa and volume above 10.0 m3 can be supplied based on a specific calculation.
The heating medium flows in a heating insert, which is a two-way insert made of Cu pipes or Fe pipes. The vertical water heaters with diameters up to 1,200 mm are placed on three supports, while the water heaters with diameters above 1,400 mm rest on four supports. If required, the horizontal heater can be placed on a bolster according to customer’s specifications.
The heaters have a neck for input and output of water or steam, and welded-on pieces for circulation, thermometer, pressure gauge, control sensor, settling and venting. Any order must clearly indicate the size and locating of each inlet and outlet (DN 2) according to customer’s specifications.
Please, be sure to indicate a catalogue number of the water heater, designation according to the heating medium, pressures and temperatures in the casing and insert, and size of the heat-delivery surface. The heater casing is coated with primer; an internal finish by either galvanizing or plastic coating is possible upon request. The heaters have environmentally sound coating (water dilutable).
For technical and design data of the standard water heaters, please see the catalogue tables.
Heat energy savings in hot service water production
Heat energy savings in HSW production by a storage water heater are possible when the temperature of the water being warmed is increased to 80 °C or more. This will increase the heating capacity of the heater. We can ensure the required temperature of the outlet water leaving the heater between 35 and 55 °C by mounting of a thermostatic mixing valve between inlet and outlet water piping.
However, this will convert a HSW water heater to equipment for technology use, which is therefore classified as dedicated equipment with necessary certification. Nevertheless, the products are cost-effective. Our Company supplies the water heaters of all sizes and parameters.
Production of HSW using enhanced parameters: Advantages
Decrease of heater volume by increasing heat capacity;
Reducing heat loss in distribution systems;
Reducing numbers of Legionella bacteria occurring under the temperature below 55°C;
Option to set up constant temperature required as well as decrease separation and sedimentation of scale in the piping.

PHONE.: +420 499 407 407